Another beautiful 3 phase mains supply board upgrade by Limassol Electrician 24/7. This upgrade replaced the old obsolete BACO 500ma AC RCBO that unfortunately still exists in many homes across Cyprus, potentially very dangerous and in this case showed clear signs of burning between two phases.
Bitcoin electrician Cyprus
Contact the Bitcoin electrician in Limassol Cyprus, [email protected]
Off-grid Photovoltaic PV solar systems Electrician in Limassol. PV solar systems for land owners in Limassol. Off-grid solar systems Cyprus, Limassol Photovoltaic (PV) electrician. Solar panels, MPPT charge controllers, lead acid and LiFePO4 12v deep discharge solar batteries, solar cable, MC4 connectors, 24v and 48v inverters.
Email [email protected] We specialise in 48V off grid solar systems, safer and more efficient than 12V or 24V off grid solar electricity systems.
48V to 230V inverters Cyprus, 1500 watts to 4000 watts, U.K. 13 amp socket outlet correct for Cyprus electrical system.
Nature rejuvenation, explore Cyprus nature with professional guides. Enjoy sunset outdoor dinner and delicious Cyprus wines. Rejuvenation Hiking Tours, English and Russian language excursions, Limassol mountains 🇷🇺 🇨🇾 www.rejuvenationhiking.com
House in the Troodos mountains we got called out to visit, main RCBO was tripping due to Earth leakage faults. A local Cypriot electrician thought it ok to connect the incoming single phase power to a 3 phase RCBO, to make it work he connected all three phase connection to the single incoming phase. This is by far one of the worst and most dangerous main RCBO connections we've seen in Cyprus, note all the exposed live parts and connections. Pay cheap, this is what you get in Cyprus.
Don't take such risks with your electrical supply, call the number one professional electrical service electricians in Cyprus, Limassol Electrician 24/7, tel 94449354. It is inevitable that AFDD's will in the near future become a standard requirement for new consumer init installations. Limassol Electrician 24/7 is one of the first professional electrical contractors in Cyprus to offer customers the choice of AFDD RCBO MCB's for the ultimate in domestic wiring circuit protection.
BS 7671:2018+A2:2022 Regulation 421.1.7 now requires arc fault detection devices (AFDDs) conforming to BS EN 62606 to be provided for single-phase AC circuits supplying socket-outlets with a rating not exceeding 32 A in the following installations: ● Higher Risk Residential Buildings (HRRB) ● Houses in Multiple Occupation (HMO) ● Purpose-built student accommodation ● Care homes HRRBs are assumed to be residential buildings over 18 m in height or in excess of six storeys, whichever is met first.
Limassol Electrician 24/7 called to a beautiful house in Fasoula, Limassol, problems with a 3 pole (3 phase) circuit breaker that was tripping inside the property at the ground floor fuse board (main distribution consumers unit).
Upon testing we found this breaker was the main supply MCB supplying another consumer unit in the swimming pool pump room. This consumer unit was found to be in very poor and unsafe condition, the cover was missing and no where to be found, and clear signs of water staining on many of the MCB's (miniature circuit breakers).
Our final report will recommend a full rebuild of the roof for the pump room to ensure water never enters any of the electrical equipment for the swimming pool, plus a full rebuild of this 3 phase board to comply with the latest regulations of BS: 7671. BeforeThis is how we found it, a recent 3 phase fuse board installation by a "Cyprus master electrician", incorrect circuit breakers with NO RCD PROTECTION as required by current wiring regulations. And just look at the junction box this electrician made, 3 phase connections leading to the fuse board in connectors! AfterFull rebuild of the mess we found and removal of the terribly unsafe junction box connections. Now all the circuit wiring leads directly into the rebuilt fuse board and each circuit is protected by a 30ma RCBO circuit breaker as required by safety wiring regulations. Also installed is a 4 pole SPD (surge protection device).
For all your circuit protection needs, single phase and 3 phase, indoor consumer units and outside main switch, professional wiring upgrades to comply with current wiring safety regulations, call Limassol Electrician 24/7.
Limassol MTB Adventures - Sponsored by Limassol Electrician 24/7 Cyprus
Electric vehicle charger wallbox installations in Paphos by English speaking licensed electrician. All makes of EV, Toyota, Nissan, BMW, Tesla.
|